DUAL CHANNEL
for heating AND hot water
Installation and User Instructions
UP2 Dual Channel:Layout 1
21/10/2020 Page 1
06490197001 ISSD
Lifestyle
Dual Channel
Programmer
INSTALLATION INSTRUCTIONS
PLEASE NOTE: INSTALLATION MUST ONLY BE
CARRIED OUT BY A QUALIFIED ELECTRICIAN OR
HEATING ENGINEER.
MAKE SURE MAINS INPUT HAS A 3 AMP FUSE.
Rated impulse voltage
2.5kV
The Lifestyle Programmer conforms to the essential
requirements of these Directives:
2014/30/EU – Electromagnetic Compatibility Directive
2014/35/EU – Low Voltage Directive
2012/19/EU WEEE Directive
2006/66/EC Battery Directive
2
UP2 Dual Channel:Layout 1
21/10/20 Page 2
TECHNICAL DATA
LP241Si, LP522Si & LP722Si PROGRAMMERS
LP111Si & LP711Si
TIMESWITCHES
Voltage
230V a.c. +10% - 10% 50Hz
Programmer Rating
2 (1) A 230V a.c. each switch
Timeswitch Rating
2 (1) A 230V a.c.
Ambient temp
Operating: 0º to 45ºC
Storage: -20ºC to 50ºC
Without mains power
Display: blank
Time: always kept
Program times: always preserved
Programming resolution
1 minute
Wiring
Fixed wiring only, to comply with
current IEE regulations
Maintenance Must be maintained byaqualified
electrician or heating engineer
Pollution degree
Software class
Ball pressure test
temperature
2
2
75ºC
Schneider Electric
35 Rue Joseph Monier
France- 92500 Rueil Malmaison
se.com/contact
Technical Helpline Tel: 0333 6000 622
customer.care@draytoncontrols.co.uk
Website: www.draytoncontrols.co.uk
Quick Commissioning Guide
06490197001 IssD
Schneider Electric
401 Southway Drive
Plymouth
PL6 6QT
United Kingdom
3
WIRING THE WALLPLATE
For surface wiring, snap out the cable entry strip on the bottom
edge of the wall-plate. Lifestyle units are double-insulated and
need no earth connection, but an earthing continuity (loop)
terminal is provided for convenience.
Internal wiring
UP2 Dual Channel:Layout 1
21/10/20 Page 3
FITTING A NEW WALL-PLATE
The i d ea l lo ca ti on i s
1.4 m a bo ve f lo or l ev el , w it h reasonable
li gh ti ng , go od a cc es s , no c on de ns at io n , no e xt re me s of
te mp er at ur e, a nd a s up po rt in g s urf a ce t ha t fu ll y co ve rs t he back
of t he unit.
P os i ti on w it h 70 mm c le a ra nc e to t he r ig ht , 25 mm a bo v e, and
suf fi c ie nt r oo m to a cc es s th e se cu ri ng s cr ew s underneath.
Fi x, w it h te rm in al s at t he t o p, e it he r di re ct t o a fl at w al l u si ng wall
plu g s an d no . 6 x 1" w oo ds cr ew s, o r o n a fl us h mo un ti ng single
con d ui t b
ox t yp e U A1 ( BS4 66 2) u si ng M 3. 5 x 14 b ol t s. D O NOT
USE A S UR FA CE M OU NT IN G BOX.
Loo s en t he s ec ur in g s
cre ws o n t he o ld p ro gr am me r a nd unplug
it . Ch ec k th at t he re ’s 7 0m m cl ea ra nc e t o th e ri gh t of the
wal l -p la te , an d 25 mm a b ov e it . No w pl ug the
Lifestyle
uni t into
the w a ll -p la te a nd t ig ht en t h e se cu ri ng s cr ew s. C he ck t he 3A
fus e , an d sw it ch o n th e mains.
USING AN EXISTING WALL-PLATE
BEFORE INSTALLATION
First, make sure the mains supply is switched off!

Product Specifications

Brand: Drayton
Category: Not categorized
Model: Lifestyle LP822

Do you need help?

If you need help with Drayton Lifestyle LP822, ask a question below and other users will answer you




Not categorized Drayton User Manuals

Not categorized User Manuals

Latest Not categorized User Manuals