Thank you for your purchase of the Impact EX-100A Monolight. The
EX-100A Monolight is economical and lightweight, yet durable enough to
give you many years of trouble-free service and enjoyment. Please read
these operating instructions and safety precautions carefully before
operating this equipment.
Features
β€’ Three-stop range – full power to 1/8 power, steplessly
β€’ Built-in optical slave
β€’ Modeling lamp can be set to proportional or full power
β€’ Accepts Elinchrom-style reectors and head accessories
(8-inch grid reector included)
β€’ Tactile, β€œgrippy” feel that resists slipping, scratches, and shock damage
β€’ Commonly available 1/8˝ mini-plug sync input
β€’ Low 4.3V trigger voltage – safe for any camera’s circuitry
Power Requirements
This light comes in two models; one is designed for use with 110/120V AC power in the US
and the other for 220V AC power in Europe. Neither model can be used outside of its
native power region. Both are supplied with a three-prong, grounded plug. Do not
attempt to defeat this safety feature. If necessary, use only grounded extension cords
rated for six amps or greater.
Warning
There are no user-serviceable parts inside the unit. Only qualied service engineers
should access the inside of the case (Danger – high-voltage parts inside). Avoid damage
to both the ashtube and modeling lamp. If the modeling lamp or ashtube become
cracked or damaged in any way, they should be replaced immediately. Do not use your
ash unit in an environment where moisture or ammable vapor is likely to come in
contact with the unit. Turn the power off and unplug the power cord when the unit is not
in use. Always remove the modeling lamp and replace the protective cap when
transporting the unit. Avoid strong light falling onto the slave cell as it will prevent
efcient operation. If the unit blows a fuse, a replacement fuse can be inserted in the
pull-out compartment on the back of the unit. To ensure long life of the ash capacitors,
the ash unit should be powered up and red several times at least every two months.
All images in this manual are for illustrative purposes only. Your unit may differ slightly from the one pictured.
Page 2 Page 19
10M 25M 50M 75M 100M 10Y 25Y 50Y 75Y 100Y
One-Year Limited Warranty
Mount on a stand
(1) Select a stand or support
system of suitable weight
and dimensions to ensure
stable operation of the unit.
Install Reector &
Modeling Lamp
(2) Remove the protective
cap by pressing in and
turning it counter-
clockwise. Pull the cap off
and set aside.
(3) Install the modeling
lamp by screwing it into the
threaded socket.
CAUTION: Do not touch the lamp with your bare hands. Oil residue from your ngers can
cause the surface of the lamp to heat unevenly and explode. Use white cotton gloves or a
clean cloth.
(4) Install the reector where the protective cap was before. Align the two notches on
the reector with the white guidelines on the ash unit, press the reector in and rotate
clockwise until it locks in place. Rotate the outer ring to secure the reector.
Note: Take care when tting or removing reectors or softboxes to not damage the
ashtube assembly. The ashtube is very delicate. Always switch off the unit and
disconnect the power before tting or changing lamps, ashtubes, reectors, or softboxes.
Preparing Your Monolight for Use
Page 18 Page 3
10M 25M 50M 75M 100M 10Y 25Y 50Y 75Y 100Y
1
3 4
2
Specications
EX-100A
Power Output 100 W/S
Guide Number
1
30
Output Control Range Full power to 1/8 stepless
Recycling Time 1~2 seconds
Flash Duration 1/1000 ~ 1/1500 second
Flash Ready Indicator LED and audible beep
Modeling Lamp 60W (not to exceed 100W)
Triggers Sync cable, slave sensor, test button
Trigger Voltage 4.3V
Built-in Slave Cell Yes
Color Temperature 5800Β°K Β±200Β°K
Flash Tube Plug-in type, user replaceable
Reector Mount Elinchrom-type
Sync Cable 1/8˝ phono jack
Power Source 110~120V AC, 60Hz
Circuit Protection 6.3A Fuse
Dimensions 9.5 Γ— 7.75 Γ— 5˝ (240 Γ— 198 Γ— 127 mm) – without reector
11.25 Γ— 8.25 Γ— 10.3˝ (285 Γ— 210 Γ— 262 mm) – with reector
Weight 2.6 lb. (1.2 kg)
1
Guide Number is calculated at f/8, 10ft, ISO 100, using the included reector, and is a starting point.
You should perform your own evaluations to determine the results you prefer.
Contents of carton
Carefully remove the monolight from the box. You should have the following:
β€’ monolight with protective cap and ashtube installed
β€’ 60W modeling lamp β€’ 8˝ grid reector β€’ sync cable
β€’ spare fuse β€’ power cable β€’ user manual
You may also have other items, such as a light stand, umbrella, or softbox,
if you purchased the EX-100A as part of a kit.

Product Specifications

Brand: Impact
Category: Lamp
Model: EX-100A

Do you need help?

If you need help with Impact EX-100A, ask a question below and other users will answer you




Lamp Impact User Manuals

Impact

Impact Octacool-9 Manual

17 October 2024
Impact

Impact LSP-SW10S Manual

17 October 2024
Impact

Impact FL-2-KII Manual

17 October 2024
Impact

Impact LS-CT40M Manual

17 October 2024
Impact

Impact Octa FF-OF4 Manual

17 October 2024
Impact

Impact Octacool-6 Manual

17 October 2024
Impact

Impact FRC-RLSLB Manual

17 October 2024
Impact

Impact VC-500WLN Manual

17 October 2024
Impact

Impact SF-ABRL160 Manual

17 October 2024
Impact

Impact FF-SA4 Manual

17 October 2024

Lamp User Manuals

Latest Lamp User Manuals

August

August LEC315 Manual

27 October 2024
Kanlux

Kanlux HERON II LED Manual

27 October 2024
Kanlux

Kanlux STONO 390 N Manual

27 October 2024
BeamZ

BeamZ Fuze 75 Beam Manual

26 October 2024
BeamZ

BeamZ Ignite 220 Manual

26 October 2024
Zadro

Zadro MAG10 Manual

26 October 2024
Lucide

Lucide Moda Manual

26 October 2024