Emko Eco Light Manual

Emko Thermostat Eco Light

Read below 📖 the manual in Italian for Emko Eco Light (4 pages) in the Thermostat category. This guide has been helpful for 26 people and has been rated 4.5 stars on average by 2 users

Page 1/4
3
2
1
PO1
PO2
°C
°F
/
LITE
Eco
AL1
4
5
6
PO1
PO2
°C
°F
/
LITE
Eco
AL1
1- Before mountng the devce n your
panel, make sure that the cutout s of
the rght sze.
2- Check front panel gasket poston.
3- Insert the devce through the cutout.
If the mountng clamps are on the unt,
put out them before nsertng the unt to
the panel.
4- Insert the mountng clamps to the two
of desgnated holes that located four
sdes of devce.
5- Drag the mountng clamps n
drecton 5 untl the devce completely
mmoble wthn the panel.
6- In order to remove devce push on
the mountng clamp as shown wth
arrow 6 and pull back.
Introducton Brochure. ENG EcoLITE 01 V06 10/19
DISPLAY
Process Dsplay: 16 mm Red 3 dgt LED Dsplay
Set Value Dsplay: 9 mm Orange 4 dgt LED Dsplay
Led Indcators: PO1 (Process Output-1 Status Led), PO2 (Process
Output-2 Status Led), ºC, ºF LEDs
ENVIRONMENTAL RATINGS and PHYSICAL SPECIFICATIONS
Operatng Temperature: 0...50ºC
Humdty: 0-90%RH (none condensng)
Protecton Class: IP65 at front, IP20 at rear
Weght: 150 gr.
Dmenson: 48 x 48 mm, Depth: 86,5 mm
Panel CutOut: 46 x 46 mm
Access and Change Set Values
Eco LITE, On/Off Temperature Control Unt
- 3 dgt process (PV) and 4 dgt set (SV) dsplay
- Process nput (TC,RTD)
- ON/OFF control form
- Selectable heatng and coolng functon
- Operatng type selecton wth hysteress
- Adjustment of temperature offset value
- Mnmum pullng tme adjustment for control outputs
- Password protecton for programmng mode
Eco seres temperature controllers are desgned for measurng and
controllng temperature. They can be used n many applcatons wth
ther TC and RTD temperature measurement nput, On/Off control form
and heatng and coolng selecton.
They are manly used n glass, plastc, petro-chemstry, textle,
automotve and machne producton ndustres.
SPECIFICATIONS
Process Input: TC, RTD
Thermocouple (TC): J, K, R, S, T and L (IEC584.1)(ITS90)
Termoresstance (RTD): Cu-50 and PT-100 (IEC751)(ITS90)
Measurement Range: Please refer to process nput type selecton n
process menu parameters secton.
Accuracy:
Thermocouple (TC):( ± 0.25% of full scale or ± 3ºC, whch one s
greater) ±1 dgt max.
Thermoresstance (RTD):( ± 0.25% of full scale or ± 2ºC, whch one s
greater) ±1 dgt max.
Cold Juncton Compensaton: Automatcally ±0.1°C/1°C
Lne Compensaton: Maxmum 10 Ohm
Sensor Break Protecton: Upscale
Samplng Cycle: 0.1 second
Input Flter: Programmable
Control Form: ON/OFF
ON/OFF Hysteress: It can be confgured for two control outputs
OUTPUT
Process Output - 1: Relay (5A@250VV at resstve load)
Process Output - 2: Relay (5A@250VVat resstve load)
ON/OFF TEMPERATURE CONTROL UNIT
LITE
Eco
SUPPLY VOLTAGE (It must be determned n order)
230VV (±15%) 50/60Hz - 2VA
115VV (±15%) 50/60Hz - 2VA
100-240VV 50/60Hz - 2VA
24VV(±%15) 50/60Hz - 2VA
24VW (±%15) 50/60Hz - 2VA
10...30VZ - 2W
Electrcal Wrngs
The Devce wth One Relay:
The Devce wth Two Relays:
To reduce the effect of electrcal nose on devce, low voltage lne (especally sensor
nput cable) wrng must be separetely from hgh current and voltage lne. If possble,
use shelded cable and sheld must be connected to ground only one sde.
c
LITE
Eco
1
2
3
4
5
6
7
8
9
10
11
12
13
14
C
NO
Process
Input
5A@250V
PT-100
TC
Supply
Swtch
L
N
Supply
Voltage
1A T
Fuse
PO1
(Process Output 1)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
C
NO
NO
PO1
(Process Output 1)
PO2 / AL1
(Process Output 2 or
Alarm Output 1)
Process
Input
5A@250V
5A@250V
PT-100
TC
Supply
Swtch
L
N
Supply
Voltage
1A T
Fuse
LITE
Eco
Dmensons
6 mm / 0.24 nch
80,52 mm / 3.17 nch
Maxmum 9 mm / 0.35 nch
48 mm / 1.89 nch
48 mm / 1.89 nch
PO1
PO2
°C
°F
/
LITE
Eco
AL1
Panel Mountng
PO2
PO1
AL1
AL2
°C
°F
/
Press ncrement or decrement
button to change Set1 value.
Press Enter button to save new
Set1 value and open Set2 screen.
Man Screen
PO2
PO1
AL1
AL2
°C
°F
/ PO2
PO1
AL1
AL2
°C
°F
/
Man Screen
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/ PO2
PO1
AL1
AL2
°C
°F
/
Press ncrement or decrement
button to change Set2 value.
Press Enter button to save new
Set2 value and return man screen.
Note1: User can ext from set value secton wthout savng the values by pressng
button. If no operaton for 120 seconds, devce automatcally exts from Set Value
secton.
Note2: Dsplayed set value at man screen could be changed accordng to
parameter
Note3: Set values can be adjusted between Set Value Low and Hgh Lmts.
PO2
PO1
AL1
AL2
°C
°F
/
Man Screen
PO2
PO1
AL1
AL2
°C
°F
/PO2
PO1
AL1
AL2
°C
°F
/
Password Screen
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
*1
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
*5
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
*4
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
*2
PO2
PO1
AL1
AL2
°C
°F
/ PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/ PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
*3
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
*3
*3
To enter program menu
press button
Enter Password wth
ncrement or decrement buttons.
Approve password
wth Enter button
*1 - Mnmum pullng tme parameter for Output-1( ) s not seen unless operaton
type selecton for output-1 parameter( ) s set as .
*2 - Out-2( ) parameters are not seen on devces wth one relay.
*3 - Alarm parameters( , and ) are not seen unless operaton type
selecton for output-2 parameter( ) s set as .
*4 - Mnmum pullng tme parameter for Output-2( ) s not seen unless operaton
type selecton for output-2 parameter( ) s set as .
*5 - If s dfferent from 0 and user enters to program menu wthout enterng the
password menu s not seen.
Note: User can ext from any parameter screen wthout savng the values by
pressng button. If no operaton for 120 seconds, devce automatcally return to
the man screen.
Easy Access Dagram For Program Parameters
: Output-1 Parameters
: Operaton Type Selecton for Output-1. It can be or .
(Default: )
: Hysteress Value for Output-1. It can be adjusted from %0 to %50 of
the Operaton Scale ( - ). (Default: 3)
: Set1 Value Low Lmt. Mnmum Set1 value s defned wth ths
parameter. It can be adjusted from Operaton Scale Low Lmt( ) to
Set1 Hgh Lmt( ). (Default: 0)
: Set1 Value Hgh Lmt. Maxmum Set1 value s defned wth ths
parameter. It can be adjusted from Set1 Low Lmt( ) to Operaton
Scale Hgh Lmt( ). (Default: 500)
: Mnmum Pullng Tme for Output-1. When Output-1 s nactve ths
tme must be expred for Output-1 to become actve agan. It can be
adjusted from 0 to 100 seconds. (Default: 0)
: Output-2 Parameters (Only for devces wth two relays)
: Operaton Type Selecton for Output-2. It can be , or .
(Default: )
: Hysteress Value for Output-2. It can be adjusted from %0 to %50 of
the Operaton Scale ( - ). (Default: 3)
: Alarm type selecton. See "Alarm Types" secton. (Default: )
: Set2 Value Low Lmt. Mnmum Set2 value s defned wth ths
parameter. It can be adjusted from Operaton Scale Low Lmt( ) to
Set1 Hgh Lmt( ). (Default: 0)
: Set2 Value Hgh Lmt. Maxmum Set2 value s defned wth ths
parameter. It can be adjusted from Set2 Low Lmt( ) to Operaton
Scale Hgh Lmt( ). (Default: 500)
: Mnmum Pullng Tme for Output-2. When Output-2 s nactve ths
tme must be expred for Output-2 to become actve agan. It can be
adjusted from 0 to 100 seconds. (Default: 0)
: Alarm on Delay Tme. It can be adjusted from 0 to 9999 seconds.
(Default: 0)
: Alarm off Delay Tme. It can be adjusted from 0 to 9998 seconds. If
t s hgher than 9998, s seen on the screen and alarm latchng
output s selected. In alarm latchng output mode n order to make
passve alarm outputs, press enter button at man screen. (Default: 0)
: Protecon Menu Parameters
: Password for accessng to the programmng secton. It can be
adjusted from 0 to 9999.If s 0, password screen s not seen. If
s dfferent from 0 and user enters to the menu pages wthout enterng the
password, all menus can be seen except protecton menu . But
devce does not allow to do any changes n parameters. (Default: 0)
: User default parameters. Ths parameter s used for savng all
parameters to restore later or restore all parameters saved before. If
s chosen, all parameters saved before are restored. If s chosen, all
parameters saved to restore later. If s chosen, nothng s changed.
(Default: )
: Ths parameter s used for restore factory defaults. If s chosen,
factory defaults parameters restored. If s chosen, nothng s changed.
(Default: )
Remove all nput/output connectons on termnals before
restorng parameters to user/factory defaults.
c
: Process nput type selecton. (Default: )
: J type (Fe,Cu,N) Thermocouple , -199ºC,900ºC ; -199ºF,999ºF
: J type (Fe,Cu,N) Thermocouple , -19.9ºC,99.9ºC ; -19.9ºF,99.9ºF
: K type (N,Cr,N) Thermocouple , -199ºC,999ºC ; -199ºF,999ºF
: K type (N,Cr,N) Thermocouple , -19.9ºC,99.9ºC ; -19.9ºF,99.9ºF
: R type (Pt13%RhPt) Thermocouple , 0ºC,999ºC ; 32ºF,999ºF
: R type (Pt13%RhPt) Thermocouple , 0.0ºC,99.9ºC ; 32.0ºF,99.9ºF
: S type (Pt10%RhPt) Thermocouple , 0ºC,999ºC ; 32ºF,999ºF
: S type (Pt10%RhPt) Thermocouple , 0.0ºC,99.9ºC ; 32.0ºF,99.9ºF
: T type (Cu,Cu,N) Thermocouple , -199ºC,400ºC ; -199ºF,752ºF
: T type (Cu,Cu,N) Thermocouple , -19.9ºC,99.9ºC ; -19.9ºF,99.9
: L type (N,Cr,Co / N,Fe,Mn,Cu) Thermocouple , -150ºC,800ºC ;
-199ºF,999ºF
: L type (N,Cr,Co / N,Fe,Mn,Cu) Thermocouple , -19.9ºC,99.9ºC ;
-19.9ºF,99.9ºF
: Cu-50 , -199ºC,200ºC ; -199ºF,392ºF
: Cu-50 , -19.9ºC,99.9ºC ; -19.9ºF,99.9ºF
: Pt-100 , -199ºC,650ºC ; -199ºF,999ºF
: Pt-100 , -19.9ºC,99.9ºC ; -19.9ºF,99.9ºF
: Unt Selecton. or can be chosen. (Default: )
: Operaton Scale mnmum (Low Lmt) value. It changes accordng
to the process nput type and scale. (Default: -199)
: Operaton Scale maxmum (Hgh Lmt) value. It changes accordng
to the process nput type and scale. (Default: 900)
: Dsplay offset for process value. It can be adjusted from -10% of
scale to 10% ofscale. It s added to the process dsplay value. (Default: 0)
: Defne flter tme(sec) for dsplayed value. (Default: 1.0)
: Selecton of whch set value dsplayed at man screen.
(Default: )
: Process Menu Parameters
Installaton
In package,
-One pece unt
-Two peces mountng clamp
-One pece nstructon manual
A vsual nspecton of ths product for possble damage occured
durng shpment s recommended before nstallaton. It s your
responsblty to ensure that qualfed mechancal and electrcal
techncans nstall ths product.
If there s danger of serous accdent resultng from a falure or defect
n ths unt, power off the system and the electrcal connecton of the
devce from the system.
The unt s normally suppled wthout a power swtch or a fuse. Use
power swtch and fuse as requred.
Be sure to use the rated power supply voltage to protect the unt
aganst damage and to prevent falure.
Keep the power off untl all of the wrng s completed so that electrc
shock and trouble wth the unt can be prevented.
Never attempt to dsassemble, modfy or repar ths unt. Tamperng
wth the unt may results n malfuncton, electrc shock or fre.
Do not use the unt n combustble or explosve gaseous
atmospheres. Durng the equpment s putted n hole on the metal
panel whle mechancal nstallaton some metal burrs can cause
njury on hands, you must be careful.
Montage of the product on a system must be done wth t’s mountng
clamp. Do not do the montage of the devce wth napproprate
mountng clamp. Be sure that devce wll not fall whle dong the
montage.
It s your responsblty f ths equpment s used n a manner not
specfed n ths nstructon manual.
Before begnnng nstallaton of ths product, please
read the nstructon manual and warnngs below
carefully.
Warranty
EMKO Elektronk warrants that the equpment delvered s free from
defects n materal and workmanshp. Ths warranty s provded for a
perod of two years. The warranty perod starts from the delvery
date.
Ths warranty s n force f duty and responsbltes whch are
determned n warranty document and nstructon manual performs
by the customer completely.
Mantenance
Repars should only be performed by traned and specalzed
personnel. Cut power to the devce before accessng nternal parts.
Do not clean the case wth hydrocarbon-based solvents (Petrol,
Trchlorethylene etc.). Use of these solvents can reduce the
mechancal relablty of the devce. Use a cloth dampened n ethyl
alcohol or water to clean the external plastc case.
Other Informatons
Manufacturer Informaton:
Emko Elektronk Sanay ve Tcaret A.Ş.
Demrtaş Organze Sanay Bölges Karanfl Sk. No:6 16369
BURSA/TURKEY
Phone: +90 224 261 1900
Fax: +90 224 261 1912
a
Repar and Mantenance Servce Informaton:
Emko Elektronk Sanay ve Tcaret A.Ş.
Demrtaş Organze Sanay Bölges Karanfl Sk. No:6 16369
BURSA/TURKEY
Phone: +90 224 261 1900
Fax : +90 224 261 1912
Alarm Types
Set 2
Alarm
Output
Process Value
Process Hgh
Alarm
Process Low
Alarm
Set 2
Alarm
Output
Process Value
Devaton Low
Alarm
Alarm
Output
Process Value
Set 1Set 1 Set 2
Devaton Hgh
Alarm
Set 1 Set 1 Set 2
Alarm
Output
Process Value
Devaton Band
Alarm
Set 1 Set 2 Set 1 Set 1 Set 2
Alarm
Output
Process Value
Devaton Range
Alarm
Set 1 Set 2 Set 1 Set 1 Set 2
Alarm
Output
Process Value
Set 1 Set 2 Set 1
Devaton Range
Hgh Alarm
Alarm
Output
Process Value
1-Sensor falure n analog nputs. Sensor connecton s wrong or there
s no sensor connecton.
a
2-If programmng secton enterng password s dfferent from “0” and
user accesses to the parameter by enter button wthout enterng the
password and wants to change a parameter, the warnng message s
shown on the bottom dsplay as shown on the left. Devce does not
allow to do any changes wthout enterng the password correctly.
a
3-If value that s read from the analog nput s lower than process set
low lmt parameter value ( ), value on the top dsplay starts to blnk
as shown on the pcture.
a
4-If value that s read from the analog nput s hgher than process set
hgh lmt parameter value ( ), value on the top dsplay starts to
blnk as shown on the pcture.
a
5-If value that s read from the analog nput s lower than sensor scale
low lmt, value on the top dsplay starts to blnk as shown on the
pcture.
a
6-If value that s read from the analog nput s hgher than sensor scale
hgh lmt, value on the top dsplay starts to blnk as shown on the
pcture.
PO2
PO1
AL1
AL2
°C
°F
/
Error Messages
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
Before commssonng the devce, parameters must be set n
accordance wth desred use. Incomplete or ncorrect confguraton
can cause dangerous stuatons.
Because of lmted mechancal lfe of relay output contact, SSR
output s recommended whch the devce use PID control algortm.
The devce wth ON/OFF control algortm, hysteress parameter must
be set a sutable value for your system, to avod too much relay
swtchng.
Vac,
Vdc,
Vdc or Vac can be appled
Orderng Informaton
Eco LITE ( 48x48 DIN 1/16 )
Dmenson
48x48 DIN 1/16
A
4
A
4 .
B
.
C
.
D
0 .
E
0
Outputs-1
1R
1 x Relay Output (5A@250VV at Resstve Load) (NO,C)
C
2R
2 x Relay Output (5A@250VV at Resstve Load) (NO,NO,C)
Supply VoltageB
10...30VZ
115VV (±%15) 50/60Hz
230VV (±%15) 50/60Hz
3
5
6
100-240VV 50/60Hz1
24VV (±%15) 50/60Hz
Customer
7
9
24VW (±%15) 50/60Hz2

Product Specifications

Brand: Emko
Category: Thermostat
Model: Eco Light

Do you need help?

If you need help with Emko Eco Light, ask a question below and other users will answer you




Thermostat Emko User Manuals

Emko

Emko ESD-9950-N Manual

18 October 2024
Emko

Emko Eco Light Manual

15 October 2024

Thermostat User Manuals

Latest Thermostat User Manuals

Heatmiser

Heatmiser PRT-ETS Manual

25 October 2024
Heatmiser

Heatmiser PRT-W Manual

25 October 2024
Heatmiser

Heatmiser PRTHW Manual

25 October 2024
Heatmiser

Heatmiser PRT-EWTS Manual

25 October 2024
Heatmiser

Heatmiser DT-N Manual

25 October 2024
Heatmiser

Heatmiser DT-EW Manual

25 October 2024
Heatmiser

Heatmiser PRTHW-WTS Manual

25 October 2024
Heatmiser

Heatmiser PRT-RPTS Manual

25 October 2024
Heatmiser

Heatmiser PRT-RP Manual

25 October 2024
Heatmiser

Heatmiser PRT-B Manual

25 October 2024