Installation and Operation Manual
THE EXPERTS IN ROOM AIR CONDITIONING
230 VOLT PDH09K3SGR3, PDH12K3SGR3
265 VOLT PDH09R3SGR3, PDH12R3SGR3
Chassis Models
ZoneAire Premier
®
R-32 Series
PTAC
Packaged Terminal Air
Conditioners & Heat Pumps

2
US
C
A. IMPORTANT SAFETY AND GENERAL INFORMATION ................. 3
A.1 Introduction ............................................................................. 3
A.2 • Safety Warnings ................................................................... 3
A.3 Warning For Using R32 Refrigerant ..................................... 5
A.4 Importance of a Quality Installation ..................................... 7
A.5 Product Inspection ................................................................. 7
A.5 Model Identification Guide ..................................................... 7
A.6 Unit Features ........................................................................... 7
B. SPECIFICATIONS ................................................................................. 9
B.1 Major Components and Dimensions .................................... 9
B.2 Product Data Information ..................................................... 9
C. INSTALLATION OF THE UNIT ...........................................................10
C.1 Pre-Installation Checkpoints ...............................................10
C.3 Choosing a Location ..............................................................11
C.4 Install Unit .............................................................................13
C.4.2 External Drain Kit Installation .........................................14
C.4.3 Wall Sleeve Installation Instructions (PDXWS) ..............................15
C.4.4 Standard Grille Instructions .............................................19
C.5 Chassis Install ....................................................................... 20
E. ELECTRICAL ........................................................................................ 22
E.1 Electrical Safety Information ...............................................22
E.2 Power Cord LCDI Test .........................................................22
E.3 Electrical Wiring ........................................................................................... 23
E.4 How To Connect .....................................................................25
F. REMOTE THERMOSTATS................................................................... 26
F.1 Install Thermostat ........................................................................................ 26
F.2 Terminal Connections ........................................................... 27
J. STARTUP AND OPERATION ..............................................................27
J.1 Final Inspection ..................................................................... 27
J.2 Air Flow Selection and Adjustment ....................................28
J.3 Dip Switches ..........................................................................29
J.4 Control Panel Operation ....................................................... 30
J.5 Allocation Mode ..................................................................... 31
M. TROUBLESHOOTING .........................................................................32
M.1. Troubleshooting Tips ...................................................... 32
M.2 Diagnostic Codes ............................................................. 33
P. ACCESSORIES .....................................................................................34
R . INFORMATION FOR THE OWNER ...................................................36
R.2 Routine Maintenance ...........................................................36
R.3 Qualification Of Workers ......................................................36
R.3 Warranty ................................................................................37
CAUTION: Do Not Operate Equipment During Active Stages Of Construction
To ensure proper operation, Friedrich requires that all equipment is not operated during active construction phases. This includes active
stages of completing framing, drywalling, spackling, sanding, painting, flooring, and moulding in the equipment’s designated conditioning
space. The use of this equipment during construction could result in premature failure of the components and/or system and is in violation of
our standard warranty guidelines. The operation of newly installed equipment during construction will accelerate the commencement and/or
termination of the warranty period.
Register your Air Conditioner
Model information can be found on the name plate.
Please complete and mail the owner registration card furnished
with this product, or register online at www.friedrich.com.
For your future convenience, record the model information .
Model Number ________________________
Serial Number ________________________
WARNING ADVERTENCIA ATTENTION
• RISK OF FIRE OR
EXPLOSION
• FLAMMABLE REFIGERANT
USED
• REPAIRS MAY ONLY BE
PERFORMED BY TRAINED
PERSONNEL
• CONSULT SERVICE
MANUAL BEFORE
ATTEMPTING REPAIRS. ALL
SAFETY PRECAUIONS MUST
BE FOLLOWED
• DO NOT PUNCTURE
TUBING
• DISPOSE OF UNIT
PROPERLY IN ACCORDANCE
WITH FEDERAL OR LOCAL
REGULATIONS
• ONLY USE A2L APPROVED
SERVICE EQUIPMENT
• RIESGO DE FUEGO
• REFIGERANTE INFLAMABLE
UTILZADO
• PARA SER REPARDO
UNICAMENTE POR PERSONAL
DE SERVICIO CAPACITADO
• CONSULTE EL MANUAL
DE REPARACION DEL
PROPIETARIO ANTES
DE INTENTAR REPARAR
ESTE PRODUCTO. SE
DEBEN SEGUIR TODAS
LAS PRECAUCCIONES DE
SEGURIDAD
• NO PERFORE LA TUBERIA
DE REFIGERANTE
• DESECHE
APROPIADAMENTE DE
ACUERDO CON LAS
REGULACIONES FEDERALES
O LOCALES
• RISQUE D’INCENDIE
• REFRIGERANT
INFLAMMABLE UTILISE
• A REPARER UNIQUEMENT
PAR DU PERSONNELDE
SERVICE QUALIFIE
• CONSULTAR LE MANUEL
DE REPARATION/GUIDE
DU PROPRIETARE AVANTE
DE TENTER DE REPARER
CE PRODUIT. TOUTES LES
PRECAUTIONS DE SECURITE
DOIVENT ETRE SUIVIES
• NE PAS PERFORER LE
TUYAU DE REFIGERANT
• ELIMINER CORRECTEMENT
CONFORMENT AUX
REGLEMENTS FEDERAUX OU
LOCAUX

3
A. IMPORTANT SAFETY AND GENERAL INFORMATION
A.1 Introduction
This booklet contains the installation and operating instructions for your Air Conditioning unit. There are some precautions that should be taken
to ensure proper operation. Improper installation can result in unsatisfactory operation or dangerous conditions.
Read this booklet and any instructions packaged with separate equipment required to make up the system prior to installation. Give this booklet
to the owner and explain its provisions. The owner should retain this booklet for future reference.
A.2 • Safety Warnings
WARNING: The manufacturer’s warranty does not cover
any damage or defect to the air conditioner caused by the attachment
or use of any components, accessories or devices (other than those
authorized by the manufacturer) into, onto or in conjunction with the
air conditioner. You should be aware that the use of
unauthorized components, accessories or devices may
adversely affect the operation of the air conditioner
and may also endanger life and property. The
manufacturer disclaims any responsibility for such loss
or injury resulting from the use of such unauthorized
components, accessories or devices.
WARNING:Electrical Shock Hazard
Disconnect all power to the unit before starting maintenance. All
electrical connections and wiring MUST be installed by a qualified
electrician and conform to the National Code and all local codes
which have jurisdiction. Failure to do so can result in property
damage, severe electrical shock or death.
WARNING: Read Installation Manual
Please read this manual thoroughly prior to equipment
installation or operation. It is the installer’s resposibility
to properly apply and install the equipment. Installation
must be in conformance with the NFPA 70-2023 national
electric code or current edition, International Mechanic
code 2021 or current edition, and any other local or
national codes.
WARNING: Safety First
Do not remove, disable, or bypass this unit’s safety
devices. Doing so may cause fire, injuries, or death.
WARNING ADVERTENCIA ATTENTION
• RISK OF FIRE OR
EXPLOSION
• FLAMMABLE REFIGERANT
USED
• REPAIRS MAY ONLY BE
PERFORMED BY TRAINED
PERSONNEL
• CONSULT SERVICE
MANUAL BEFORE
ATTEMPTING REPAIRS. ALL
SAFETY PRECAUIONS MUST
BE FOLLOWED
• DO NOT PUNCTURE
TUBING
• DISPOSE OF UNIT
PROPERLY IN ACCORDANCE
WITH FEDERAL OR LOCAL
REGULATIONS
• ONLY USE A2L APPROVED
SERVICE EQUIPMENT
• RIESGO DE FUEGO
• REFIGERANTE INFLAMABLE
UTILZADO
• PARA SER REPARDO
UNICAMENTE POR PERSONAL
DE SERVICIO CAPACITADO
• CONSULTE EL MANUAL
DE REPARACION DEL
PROPIETARIO ANTES
DE INTENTAR REPARAR
ESTE PRODUCTO. SE
DEBEN SEGUIR TODAS
LAS PRECAUCCIONES DE
SEGURIDAD
• NO PERFORE LA TUBERIA
DE REFIGERANTE
• DESECHE
APROPIADAMENTE DE
ACUERDO CON LAS
REGULACIONES FEDERALES
O LOCALES
• RISQUE D’INCENDIE
• REFRIGERANT
INFLAMMABLE UTILISE
• A REPARER UNIQUEMENT
PAR DU PERSONNELDE
SERVICE QUALIFIE
• CONSULTAR LE MANUEL
DE REPARATION/GUIDE
DU PROPRIETARE AVANTE
DE TENTER DE REPARER
CE PRODUIT. TOUTES LES
PRECAUTIONS DE SECURITE
DOIVENT ETRE SUIVIES
• NE PAS PERFORER LE
TUYAU DE REFIGERANT
• ELIMINER CORRECTEMENT
CONFORMENT AUX
REGLEMENTS FEDERAUX OU
LOCAUX
Product Specifications
Brand: | Friedrich |
Category: | Air conditioning |
Model: | PDE07R3SG |
Do you need help?
If you need help with Friedrich PDE07R3SG, ask a question below and other users will answer you
Air conditioning Friedrich User Manuals

13 October 2024

13 October 2024

13 October 2024
Air conditioning User Manuals
- Air conditioning Candy
- Air conditioning Electrolux
- Air conditioning Samsung
- Air conditioning LG
- Air conditioning Panasonic
- Air conditioning Delonghi
- Air conditioning Koldfront
- Air conditioning Arcelik
- Air conditioning Danby
- Air conditioning Hisense
- Air conditioning Gree
- Air conditioning TCL
- Air conditioning Hotpoint
- Air conditioning Whirlpool
- Air conditioning Cecotec
- Air conditioning Comfee
- Air conditioning Kogan
- Air conditioning SereneLife
- Air conditioning Create
- Air conditioning Midea
- Air conditioning Sauber
- Air conditioning Haier
- Air conditioning Olimpia Splendid
- Air conditioning Westinghouse
- Air conditioning Sencor
- Air conditioning Electroline
- Air conditioning Fujitsu
- Air conditioning Orava
- Air conditioning Mistral
- Air conditioning Khind
- Air conditioning Amana
- Air conditioning Dimplex
- Air conditioning Whynter
- Air conditioning GE
- Air conditioning Hitachi
- Air conditioning Hyundai
- Air conditioning VänEE
- Air conditioning Daikin
- Air conditioning Be Cool
- Air conditioning Avidsen
- Air conditioning Mitsubishi
- Air conditioning Tristar
- Air conditioning Dometic
- Air conditioning Eldom
- Air conditioning Elba
- Air conditioning Philco
- Air conditioning Black And Decker
- Air conditioning Wilfa
- Air conditioning Heinner
- Air conditioning SEEGER
- Air conditioning IFB
- Air conditioning Duracraft
- Air conditioning Home Electric
- Air conditioning Milectric
- Air conditioning LERAN
- Air conditioning Perfect Aire
- Air conditioning Argoclima
- Air conditioning ARCTIC WIND
- Air conditioning Trisa
- Air conditioning Daizuki
- Air conditioning Mayer
- Air conditioning Be Quiet!
- Air conditioning BOSFOR
- Air conditioning KDK
- Air conditioning Aconatic
- Air conditioning AireMax
- Air conditioning Profile
- Air conditioning Keystone
- Air conditioning Honeywell
- Air conditioning Ravanson
- Air conditioning ActronAir
- Air conditioning Woods
- Air conditioning Aspes
- Air conditioning Fuave
- Air conditioning Yamazen
- Air conditioning Cool-Space
- Air conditioning GoldAir
- Air conditioning KuulAire
- Air conditioning SHE
- Air conditioning BLUEPALM
Latest Air conditioning User Manuals

27 October 2024

27 October 2024

27 October 2024

27 October 2024

27 October 2024

27 October 2024

27 October 2024

27 October 2024

26 October 2024

26 October 2024